• KNX bus communication (S-mode and LTE mode)
• Backlit display
• 2P / PI / P control
• Outputs for On/Off, PWM, 3-position or DC 0...10 V control
• Outputs for 3-speed, 1-speed, or DC (DC 0...10 V) fan
• 3 multifunctional inputs for keycard contact, external sensor, etc.
• Operating modes: Comfort, Economy and Protection
• Automatic or manual fan speed control
• Automatic or manual heating / cooling changeover
• Minimum and maximum limitation of room temperature setpoint
• Control depending on the room or the return air temperature
• Selectable relay output functions (RDG160KN)
• Adjustable commissioning and control parameters
• Commissioning with Synco ACS, ETS or via local HMI
• Integration into Synco
• Integration into Desigo via group addressing (ETS) or via individual addressing
• Integration into third-party system via group addressing (ETS)
• Operating voltage: RG100KN: AC 230 V RDG160KN: AC 24 V
Use
The RDG1...KN room thermostats are designed for use with the following types of system:
Fan coil units via On/Off or modulating / DC control outputs:
• 2-pipe system
• 2-pipe system with electric heater
• 2-pipe system and radiator / floor heating
• 4-pipe system
• 4-pipe system with electric heater (RDG100KN)
• 2-stage heating or cooling system
Chilled / heated ceilings (or radiators) via On/Off or modulating / DC control outputs:
• Chilled / heated ceiling
• Chilled / heated ceiling with electric heater
• Chilled / heated ceiling and radiator / floor heating
• Chilled / heated ceiling, 2-stage cooling or heating Compressor application via On/Off control (RDG160KN)
• Compressors in DX-type equipment
• Compressors in DX-type equipment with electric heater
• Compressors in DX-type equipment with Radiator
• 2-stage compressors in DX-type equipment for heating or cooling
The RDG100KN controls ...
• One single or 3-speed fan
• One or two On/Off / PWM / 3-position valve actuators
• One valve actuator and one electric heater / Radiator
The RDG160KN controls ...
• One single, 3-speed or DC 0...10 V fan
• One or two On/Off valve actuators / el. Heater / radiator with DC fan
• One or two DC valve actuators / el. Heater / radiator with DC fan
• One or two DC valve actuators / el. Heater / radiator with 1 / 3-speed fan
• One On/Off valve actuator, one DC valve actuator with DC fan
• 1 or 2-stage compressor in DX-type equipment, with electric heater / radiator
Used in systems with:
• Heating or cooling mode
• Automatic heating/cooling changeover
• Manual heating/cooling changeover
• Heating and cooling mode (e.g. 4-pipe system)
The room thermostats are delivered with a fixed set of applications. The relevant application is selected and activated during commissioning using one of the following tools:
• Synco ACS
• ETS
• Local DIP switch and HMI
Model
RDG100KN | Room Controller, Backlit LCD, H/C, AC 230V, Auto/Man.C/Over, 3 Speed Fan, On/Off or 3-Pos Outputs with KNX Communications (S55770-T163) |
RDG160KN | Room Controller, Backlit LCD, H/C, AC 24V, Auto/Man.C/Over, 3 Speed Fan, 0-10V Output (S55770-T297) |
RDG165KN | Room Controller, Backlit LCD, H/C, AC 24V, Auto/Man.C/Over, 3 Speed Fan, 0-10V Output, with humidity sensor & control (S55770-T347) |